ES411AM2FGP 12V PUSH & PULL SOLENOID 2 WIRE
The ES411AM2FGP 12V PUSH & PULL SOLENOID 2 WIRE operates the fuel stop or control lever on diesel engines.
About this part
A stop solenoid moves the fuel control when energised (or de-energised, depending on the type) so the controller can start and stop the engine electrically. Push and pull types differ in the direction the plunger moves.
When to replace it
- Engine will not stop, or will not run once started
- Solenoid clicking without moving the lever
- Burnt coil
Before you order
Match the voltage, push or pull action, the number of wires and the mounting to the original. A three-wire solenoid has separate pull-in and hold coils.
Not sure it is the right one? A photo of the old part and the nameplate of the machine it came off is usually all the counter needs to confirm a match.
Questions
Why does my solenoid burn out?
Often because the pull-in coil stays energised. Three-wire solenoids need the controller to drop the pull-in coil after a moment.
Specifications
| Part number | ES411AM2FGP 12V |
|---|---|
| Brand | IEP Power Products |
| Range | Solenoids |
| Action | Push-pull |
| Wires | 2 |
Not sure it fits?
Send us the number on your old part, or a photo with the engine or alternator nameplate, and we'll confirm the match.
WhatsApp Mieke